Images of equipment used during the research

Please click on any image to enlarge

  • collage image title

    Figure 1

    Medicine cabinet used for presenting medications in the quasi-practice environment

  • collage image title

    Figure 2

    Medicine cupboard stocked with tablet, capsule, liquid medicine and injection containers

  • collage image title

    Figure 3

    Tablet and capsule problem solving station in the quasi-practice environment

  • collage image title

    Figure 4

    Tablet and capsule reference assessment solutions used in the quasi-practice environment

  • collage image title

    Figure 5

    Oral liquid medicine problem solving station in the quasi-practice environment

  • collage image title

    Figure 6

    Oral liquid medicine conceptual, calculation & technical measurement competence assessment in the quasi-practice environment

  • collage image title

    Figure 7

    Oral liquid medicine reference assessment solutions used in the quasi-practice environment

  • collage image title

    Figure 8

    Oral liquid medicine reference assessment solutions used in the quasi-practice environment

  • collage image title

    Figure 9

    Injection conceptual, calculation & technical measurement competence problem solving station in the quasi-practice environment

  • collage image title

    Figure 10

    IV infusion conceptual, calculation & technical measurement competence mL per hour & drop per minute flow rate problem solving station in the quasi-practice environment

  • collage image title

    Figure 11

    Volumetric infusion pump - for entry of mL per Hour IV infusion rate values in the quasi-practice environment

  • collage image title

    Figure 12

    Volumetric infusion pump - numerical key pad for entry of mL per Hour IV infusion rate values in the quasi-practice environment

  • collage image title

    Figure 13

    IV infusion administration set - drop chamber for observation & counting of drops per minute rates in the quasi-practice environment

  • collage image title

    Figure 14

    IV infusion administration set - roller clamp for setting & controlling drop per minute flow rates rates in the quasi-practice environment

  • collage image title

    Figure 15

    Technical measurement error - 5mL inappropriately measured in 50mL oral liquid medicine measurement pot rates in the quasi-practice environment

  • collage image title

    Figure 16

    Technical measurement error - 5mL inappropriately measured in 50mL oral liquid medicine measurement pot rates (enlarged) in the quasi-practice environment

  • collage image title

    Figure 17

    Technical measurement error - air bubble not displaced from syringe in the quasi-practice environment

  • collage image title

    Figure 18

    Technical measurement error – multiple minor air bubbles not displaced from syringe in the quasi-practice environment

  • collage image title

    Figure 19

    Technical measurement error - large air bolus not displaced from syringe in the quasi-practice environment

  • collage image title

    Figure 20

    Technical measurement error multiple air boluses not displaced from syringe in the quasi-practice environment

  • collage image title

    Figure 21

    Technical measurement error - syringe plunger drawn up to the correct numerical graduation point on syringe: no fluid drawn into the syringe (complete air bolus) in the quasi-practice environment

Images taken of equipment used during the research